Hysafe SBEP-V20: Numerical Predictions of Release Experiments Inside a Residential Garage With Passive Ventilation
Sep 2009
Publication
This work presents the results of the Standard Benchmark Exercise Problem (SBEP) V20 of Work Package 6 (WP6) of HySafe Network of Excellence (NoE) co-funded by the European Commission in the frame of evaluating the quality and suitability of codes models and user practices by comparative assessments of code results. The benchmark problem SBEP-V20 covers release scenarios that were experimentally investigated in the past using helium as a substitute to hydrogen. The aim of the experimental investigations was to determine the ventilation requirements for parking hydrogen fuelled vehicles in residential garages. Helium was released under the vehicle for 2 h with 7.200 l/h flow rate. The leak rate corresponded to a 20% drop of the peak power of a 50 kW fuel cell vehicle. Three double vent garage door geometries are considered in this numerical investigation. In each case the vents are located at the top and bottom of the garage door. The vents vary only in height. In the first case the height of the vents is 0.063 m in the second 0.241 m and in the third 0.495 m. Four HySafe partners participated in this benchmark. The following CFD packages with the respective models were applied to simulate the experiments: ADREA-HF using k–ɛ model by partner NCSRD FLACS using k–ɛ model by partner DNV FLUENT using k–ɛ model by partner UPM and CFX using laminar and the low-Re number SST model by partner JRC. This study compares the results predicted by the partners to the experimental measurements at four sensor locations inside the garage with an attempt to assess and validate the performance of the different numerical approaches.
Time Response of Hydrogen Sensors
Sep 2013
Publication
The efficiency of gas sensor application for facilitating the safe use of hydrogen depends to a considerable extent on the response time of the sensor to change in hydrogen concentration. The response and recovery times have been measured for five different hydrogen sensors three commercially available and two promising prototypes which operate at room temperature. Experiments according to ISO 26142 show that most of the sensors surpass much for a concentration change from clean to hydrogen containing air the demands of the standard for the response times t(90) and values of 2 to 16 s were estimated. For an opposite shift to clean air the recovery times t(10) are from 7 to 70 s. Results of transient behaviour can be fitted with an exponential approach. It can be demonstrated that results on transient behaviour depend not only from investigation method and the experimental conditions like gas changing rate and concentration jump as well as from operating parameters of sensors. In comparison to commercial MOS and MIS-FET hydrogen sensors new sensor prototypes operating at room temperature possesses in particular longer recovery times.
Composite Gas Cylinders Probabilistic Analysis of Minimum Burst and Load Cycle Requirements
Oct 2015
Publication
Gas cylinders made of composite materials receive growing popularity in light-weight applications. Current standards are mostly based on safety determination relying on minimum amounts of endured load cycles and a minimum burst pressure of a small number of specimens. This paper investigates the possibilities of a probabilistic strength assessment for safety improvements as well as cost and weight savings. The probabilistic assessment is based on destructive testing of small sized samples. The influence of sample size on uncertainty of the assessment is analysed. Furthermore methods for the assessment of in-service ageing (degradation) are discussed and displayed in performance charts.
Experimental Validation of Hydrogen Fuel−Cell and Battery−Based Hybrid Drive without DC−−DC for Light Scooter under Two Typical Driving Cycles
Dec 2021
Publication
Faced with key obstacles such as the short driving range long charging time and limited volume allowance of battery−−powered electric light scooters in Asian cities the aim of this study is to present a passive fuel cell/battery hybrid system without DC−−DC to ensure a compact volume and low cost. A novel topology structure of the passive fuel cell/battery power system for the electric light scooter is proposed and the passive power system runs only on hydrogen. The power performance and efficiency of the passive power system are evaluated by a self−developed test bench before installation into the scooters. The results of this study reveal that the characteristics of stable power output quick response and the average efficiency are as high as 88% during the Shanghainese urban driving cycle and 89.5% during the Chinese standard driving cycle. The results pre‐ sent the possibility that this passive fuel cell/battery hybrid powertrain system without DC−DC is practical for commercial scooters.
3D Risk Management for Hydrogen Installations (HY3DRM)
Oct 2015
Publication
This paper introduces the 3D risk management (3DRM) concept with particular emphasis on hydrogen installations (Hy3DRM). The 3DRM framework entails an integrated solution for risk management that combines a detailed site-specific 3D geometry model a computational fluid dynamics (CFD) tool for simulating flow-related accident scenarios methodology for frequency analysis and quantitative risk assessment (QRA) and state-of-the-art visualization techniques for risk communication and decision support. In order to reduce calculation time and to cover escalating accident scenarios involving structural collapse and projectiles the CFD-based consequence analysis can be complemented with empirical engineering models reduced order models or finite element analysis (FEA). The paper outlines the background for 3DRM and presents a proof-of-concept risk assessment for a hypothetical hydrogen filling station. The prototype focuses on dispersion fire and explosion scenarios resulting from loss of containment of gaseous hydrogen. The approach adopted here combines consequence assessments obtained with the CFD tool FLACS-Hydrogen from Gexcon and event frequencies estimated with the Hydrogen Risk Assessment Models (HyRAM) tool from Sandia to generate 3D risk contours for explosion pressure and radiation loads. For a given population density and set of harm criteria it is straightforward to extend the analysis to include personnel risk as well as risk-based design such as detector optimization. The discussion outlines main challenges and inherent limitations of the 3DRM concept as well as prospects for further development towards a fully integrated framework for risk management in organizations.
Blast Wave from Hydrogen Storage Rupture in a Fire
Oct 2015
Publication
This study addresses one of knowledge gaps in hydrogen safety science and engineering i.e. a predictive model for calculation of deterministic separation distances defined by the parameters of a blast wave generated by a high-pressure gas storage tank rupture in a fire. An overview of existing methods to calculate stored in a tank internal (mechanical) energy and a blast wave decay is presented. Predictions by the existing technique and an original model developed in this study which accounts for the real gas effects and combustion of the flammable gas released into the air (chemical energy) are compared against experimental data on high-pressure hydrogen tank rupture in the bonfire test. The main reason for a poor predictive capability of the existing models is the absence of combustion contribution to the blast wave strength. The developed methodology is able to reproduce experimental data on a blast wave decay after rupture of a stand-alone hydrogen tank and a tank under a vehicle. In this study the chemical energy is dynamically added to the mechanical energy and is accounted for in the energy-scaled non-dimensional distance. The fraction of the total chemical energy of combustion released to feed the blast wave is 5% and 9% however it is 1.4 and 30 times larger than the mechanical energy in the stand-alone tank test and the under-vehicle tank test respectively. The model is applied as a safety engineering tool to four typical hydrogen storage applications including onboard vehicle storage tanks and a stand-alone refuelling station storage tank. Harm criteria to people and damage criteria for buildings from a blast wave are selected by the authors from literature to demonstrate the calculation of deterministic separation distances. Safety strategies should exclude effects of fire on stationary storage vessels and require thermal protection of on-board storage to prevent dangerous consequences of high-pressure tank rupture in a fire.
Effects of Radiation on the Flame Front of Hydrogen-air Explosions
Oct 2015
Publication
The flame velocities of unconfined gas explosions depend on the cloud size and the distance from the initiating source. The mechanisms for this effect are not fully understood; a possible explanation is turbulence generated by the propagating flame front. The molecular bands in the flame front are exposed to continuously increasing radiation intensity of water bands in the interior of the reaction product ball. A first approach to verifying this assumption is described in this paper. The flame propagation was observed by high speed video techniques including time resolved spectroscopy in the UV-Vis-NIR spectral range with a time resolution up to 3000 spectra/s. Ignition flame head velocity flame contours reacting species and temperatures were evaluated. The evaluation used video brightness subtraction and 1-dimensional image contraction to obtain traces of the movements perpendicular to the direction of propagation. Flame front velocities are found to be between 16m/s and 25 m/s. Analysis focused in particular on the flame front which is not smooth. Salients emerge on the surface to result in the well-known cellular structures. The radiation of various bands from the fire ball on the reacting species is estimated to have an influence on the flame velocity depending on the distance from initiation. Evaluation of OH-band and water band spectra might indicate might indicate higher temperatures of the flame front induced by radiation of the fireball. But it is difficult to verify the effect relative to competing flame acceleration mechanisms.
Experimental Investigation of Spherical-flame Acceleration in Lean Hydrogen-air Mixtures
Oct 2015
Publication
Large-scale experiments examining spherical-flame acceleration in lean hydrogen-air mixtures were performed in a 64 m3 constant-pressure enclosure. Equivalence ratios ranging from 0.33 to 0.57 were examined using detailed front tracking for flame diameters up to 1.2 m through the use of a Background Oriented Schlieren (BOS) technique. From these measurements the critical radii for onset of instability for these mixtures on the order of 2–3 cm were obtained. In addition the laminar burning velocity and rate of flame acceleration as a function of radius were also measured.
Overview of the DOE Hydrogen Safety, Codes and Standards Program Part 1- Regulations, Codes and Standards (RCS) for Hydrogen Technologies - An Historical Overview
Oct 2015
Publication
RCS for hydrogen technologies were first developed approximately sixty years ago when hydrogen was being sold as an industrial commodity. The advent of new hydrogen technologies such as Fuel Cell Electric Vehicles (FCEVs) created a need for new RCS. These RCS have been developed with extensive support from the US DOE. These new hydrogen technologies are approaching commercial deployment and this process will produce information on RCS field performance that will create more robust RCS.
TPR-XAFS Study for Hydrogen Recombination Reaction of Platinum Metal Nanoparticle Catalysts
Sep 2017
Publication
Proper management of hydrogen gas is very important for safety of nuclear power plants. Hydrogen removal system by hydrogen recombination reaction (water formation reaction) on a catalyst is one of the candidates for avoiding hydrogen explosion. We have observed in situ and time-resolved structure change of platinum metal nanoparticle catalyst during hydrogen recombination reaction by using simultaneous measurement of temperature-programmed reaction and X-ray absorption fine structure (TPR-XAFS). A poisoning effect by carbon monoxide on catalytic activity was focused. It was found that the start of hydrogen recombination reaction is closely connected with the occurrence of the decomposition of adsorbed carbon monoxide molecules and creation of surface oxide layer on platinum metal nanoparticles.
Measurements of Effective Diffusion Coefficient of Helium and Hydrogen Through Gypsum
Sep 2011
Publication
An experimental apparatus which was based on the ¼-scale garage previously used for studying helium release and dispersion in our laboratory was used to obtain effective diffusion coefficients of helium and hydrogen (released as forming gas for safety reasons) through gypsum panel. Two types of gypsum panel were used in the experiments. Helium or forming gas was released into the enclosure from a Fischer burner1 located near the enclosure floor for a fixed duration and then terminated. Eight thermal-conductivity sensors mounted at different vertical locations above the enclosure floor were used to monitor the temporal and spatial gas concentrations. An electric fan was used inside the enclosure to mix the released gas to ensure a spatially uniform gas concentration to minimize stratification. The temporal variations of the pressure difference between the enclosure interior and the ambience were also measured. An analytical model was developed to extract the effective diffusion coefficients from the experimental data.
Risk Analysis of Complex Hydrogen Infrastructures
Oct 2015
Publication
Building a network of hydrogen refuelling stations is essential to develop the hydrogen economy within transport. Additional hydrogen is regarded a likely key component to store and convert back excess electrical power to secure future energy supply and to improve the quality of biomass-based fuels. Therefore future hydrogen supply and distribution chains will have to address several objectives. Such a complexity is a challenge for risk assessment and risk management of these chains because of the increasing interactions. Improved methods are needed to assess the supply chain as a whole. The method of “Functional modelling” is discussed in this paper. It will be shown how it could be a basis for other decision support methods for comprehensive risk and sustainability assessments.
Overview of the DOE Hydrogen Safety, Codes and Standards Program part 2- Hydrogen and Fuel Cells, Emphasizing Safety to Enable Commercialization
Oct 2015
Publication
Safety is of paramount importance in all facets of the research development demonstration and deployment work of the U.S. Department of Energy’s (DOE) Fuel Cell Technologies Program. The Safety Codes and Standards sub-program (SC&S) facilitates deployment and commercialization of fuel cell and hydrogen technologies by developing and disseminating information and knowledge resources for their safe use. A comprehensive safety management program utilizing the Hydrogen Safety Panel to raise safety consciousness at the project level and developing/disseminating a suite of safety knowledge resources is playing an integral role in DOE and SC&S efforts. This paper provides examples of accomplishments achieved while reaching a growing and diverse set of stakeholders involved in research development and demonstration; design and manufacturing; deployment and operations. The work of the Hydrogen Safety Panel highlights new knowledge and the insights gained through interaction with project teams. Various means of collaboration to enhance the value of the program’s safety knowledge tools and training resources are illustrated and the direction of future initiatives to reinforce the commitment to safety is discussed.
Mixed E-learning and Virtual Reality Pedagogical Approach for Innovative Hydrogen Safety Training for First Responders
Oct 2015
Publication
Within the scope of the HyResponse project the development of a specialised training programme is currently underway. Utilizing an andragogy approach to teaching distance learning is mixed with classroom instructors-led activities while hands-on training on a full-scale simulator is coupled with an innovative virtual reality based experience. Although the course is dedicated mainly to first responders provision has been made to incorporate not only simple table-top and drill exercises but also full-scale training involving all functional emergency response organisations at multi-agency cooperation level. The developed curriculum includes basics of hydrogen safety first responders' procedures and incident management expectations
Flammability Profiles Associated with High-pressure Hydrogen Jets Released in Close Proximity to Surfaces
Oct 2015
Publication
This paper describes experimental and numerical modelling results from an investigation into the flammability profiles associated with high pressure hydrogen jets released in close proximity to surfaces. This work was performed under a Transnational Access Agreement activity funded by the European Research Infrastructure project H2FC.<br/>The experimental programme involved ignited and unignited releases of hydrogen at pressures of 150 and 425 barg through nozzles of 1.06 and 0.64 mm respectively. The proximity of the release to a ceiling or the ground was varied and the results compared with an equivalent free-jet test. During the unignited experiments concentration profiles were measured using hydrogen sensors. During the ignited releases thermal radiation was measured using radiometers and an infra-red camera. The results show that the flammable volume and flame length increase when the release is in close proximity to a surface. The increases are quantified and the safety implications discussed.<br/>Selected experiments were modelled using the CFD model FLACS for validation purposes and a comparison of the results is also included in this paper. Similarly to experiments the CFD results show an increase in flammable volume when the release is close to a surface. The unstable atmospheric conditions during the experiments are shown to have a significant impact on the results.
Modelling Of Hydrogen Explosion on a Pressure Swing Adsorption Facility
Sep 2011
Publication
Computational fluid dynamic simulations have been performed in order to study the consequences of a hydrogen release from a pressure swing adsorption installation operating at 30 barg. The simulations were performed using FLACS-Hydrogen software from GexCon. The impact of obstruction partial confinement leak orientation and wind on the explosive cloud formation (size and explosive mass) and on explosion consequences is investigated. Overpressures resulting from ignition are calculated as a function of the time to ignition.
Steam Condensation Effect in Hydrogen Venting from a BWR Reactor Building
Oct 2015
Publication
In the accident of Fukushima Daiichi nuclear power plants hydrogen was accumulated in the reactor buildings and exploded. To prevent such explosions hydrogen venting from reactor buildings is considered. When the gas mixture is released to a reactor building through a reactor containment together with the hydrogen some amount of steam might also be released. The steam condenses if the building atmosphere is below the saturation temperature and it affects the hydrogen behaviour. In this study the condensation effect to the hydrogen venting is evaluated using CFD analyses by comparing the case where a hydrogen-nitrogen mixture is released and the case where a hydrogen-steam mixture is released.
Application of Quantitative Risk Assessment for Performance-based Permitting of Hydrogen Fueling Stations
Oct 2015
Publication
NFPA 2 Hydrogen Technologies Code allows the use of risk-informed approaches to permitting hydrogen fuelling installations through the use of performance-based evaluations of specific hydrogen hazards. However the hydrogen fuelling industry in the United States has been reluctant to implement the performance-based option because the perception is that the required effort is cost prohibitive and there is no guarantee that the Authority Having Jurisdiction (AHJ) would accept the results. This report provides a methodology for implementing a performance-based design of an outdoor hydrogen refuelling station that does not comply with specific prescriptive separation distances. Performance-based designs are a code-compliant alternative to meeting prescriptive requirements. Compliance is demonstrated by evaluating a compliant prescriptive-based refuelling station design with a performance-based design approach using Quantitative Risk Assessment (QRA) methods and hydrogen risk tools. This template utilizes the Sandia-developed QRA tool Hydrogen Risk Analysis Model (HyRAM) to calculate risk values when developing risk-equivalent designs. HyRAM combines reduced-order deterministic models that characterize hydrogen release and flame behaviour with probabilistic risk models to quantify risk values. Each project is unique and this template is not intended to cover unique site-specific characteristics. Instead example content and a methodology are provided for a representative hydrogen refuelling site which can be built upon for new hydrogen applications.
The Possibility of an Accidental Scenario for Marine Transportation of Fuel Cell Vehicle-Hydrogen Releases from TPRD by Radiant Heat From Lower Deck
Oct 2015
Publication
In case fires break out on the lower deck of a car carrier ship or a ferry the fuel cell vehicles (FCVs) parked on the upper deck may be exposed to radiant heat from the lower deck. Assuming that the thermal pressure relief device (TPRD) of an FCV hydrogen cylinder is activated by the radiant heat without the presence of flames hydrogen gas will be released by TPRD to form combustible air-fuel mixtures in the vicinity. To investigate the possibility of this accident scenario the present study investigated the relationship between radiant heat and TPRD activation time and evaluated the possibility of radiant heat causing hydrogen releases by TPRD activation under the condition of deck temperature reaching the spontaneous ignition level of the tires and other automotive parts. It was found: a) the tires as well as polypropylene and other plastic parts underwent spontaneous ignition before TPRD was activated by radiant heat and b) when finally TPRD was activated the hydrogen releases were rapidly burned by the flames of the tires and plastic parts on fire. Consequently it was concluded that the explosion of air-fuel mixtures assumed in the accident scenario does not occur in the real world.
Outward Propagation Velocity and Acceleration Characteristics in Hydrogen-air Deflagration
Oct 2015
Publication
Propagation characteristics of hydrogen-air deflagration need to be understood for an accurate risk assessment. Especially flame propagation velocity is one of the most important factors. Propagation velocity of outwardly propagating flame has been estimated from burning velocity of a flat flame considering influence of thermal expansion at a flame front; however this conventional method is not enough to estimate an actual propagation velocity because flame propagation is accelerated owing to cellular flame front caused by intrinsic instability in hydrogen-air deflagration. Therefore it is important to understand the dynamic propagation characteristics of hydrogen-air deflagration. We performed explosion tests in a closed chamber which has 300 mm diameter windows and observed flame propagation phenomena by using Schlieren photography. In the explosion experiments hydrogen-air mixtures were ignited at atmospheric pressure and room temperature and in the range of equivalence ratio from 0.2 to 1.0. Analyzing the obtained Schlieren images flame radius and flame propagation velocity were measured. As the result cellular flame fronts formed and flame propagations of hydrogen–air mixture were accelerated at the all equivalence ratios. In the case of equivalent ratio φ = 0.2 a flame floated up and could not propagate downward because the influence of buoyancy exceeded a laminar burning velocity. Based upon these propagation characteristics a favorable estimation method of flame propagation velocity including influence of flame acceleration was proposed. Moreover the influence of intrinsic instability on propagation characteristics was elucidated.