- Home
- A-Z Publications
- Publications
Publications
Evaluation of Safety Distances Related to Unconfined Hydrogen Explosions
Sep 2005
Publication
A simple approximate method for evaluation of blast effects and safety distances for unconfined hydrogen explosions is presented. The method includes models for flame speeds hydrogen distribution blast parameters and blast damage criteria. An example of the application of this methodology for hydrogen releases in three hypothetical obstructed areas with different levels of congestion is presented. The severity of the blast effect of unconfined hydrogen explosions is shown to depend strongly on the level of congestion for relatively small releases. Extremely large releases of hydrogen are predicted to be less sensitive to the congestion level.
HySafe European Network of Excellence on Hydrogen Safety
Sep 2005
Publication
Introduction and commercialisation of hydrogen as an energy carrier of the future make great demands on all aspects of safety. Safety is a critical issue for innovations as it influences the economic attractiveness and public acceptance of any new idea or product. However research and safety expertise related to hydrogen is quite fragmented in Europe. The vision of a significant increased use of hydrogen as an energy carrier in Europe could not go ahead without strengthening and merging this expertise. This was the reason for the European Commission to support the launch on the first of March 2004 of a so-called Network of Excellence (NoE) on hydrogen safety: HySafe.
Development of Hydrogen Sensors and Recombiners
Sep 2005
Publication
Hydrogen energy is very promising as it ensures a high efficiency and ecological cleanliness of energy conversion. The goal of the present work is to provide the analysis of hydrogen safety aspects and to prescribe methods of safety operation with hydrogen. The authors conducted a hazard analysis of hydrogen operation and storage in comparison with other fuels. Good ventilation is the main hydrogen operation requirement. Besides an effective way of protection against propagation of hazards (for instance leaks) is neutralization of dangerous hydrogen-air mixtures by a method of controlled catalytic combustion inside special devices so-called recombiners [1-3]. The basis of these devices is a high porosity cell material (HPCM) activated by platinum deposition. Apart from recombiners HPCM was also applied for development of hydrogen detectors intended for measurement and analysis of hydrogen concentration for hydrogen-driven transport and objects of hydrogen infrastructure (including vapor-air media at high pressure and temperatures). A system of hydrogen safety based on hydrogen detectors and hydrogen catalytic recombiners was developed. Experimental and theoretical studies of hydrogen combustion processes heat- and mass transfer and also gas flows in catalytic-activated HPCM allowed for a design optimization of recombiners and their location. Pilot hydrogen detectors and hydrogen catalytic recombiners were fabricated and their laboratory tests were successfully performed. Thus it was indicated that on condition of following the appropriate passive and active safety measures hydrogen is just as safe as the other fuels. This conclusion represents another incentive for a transition to the hydrogen energy.
Development of Tools for Risk Assessment and Risk Communication for Hydrogen Applications
Sep 2005
Publication
For decades risk assessment has been an important tool in risk management of activities in several industries world wide. It provides among others authorities and stakeholders with a sound basis for creating awareness about existing and potential hazards and risks and making decisions related to how they can prioritise and plan expenditures on risk reduction. The overall goal of the ongoing HySafe project is to contribute to the safe transition to a more sustainable development in Europe by facilitating the safe introduction of hydrogen technologies and applications. An essential element in this is the demonstration of safety: that all safety aspects related to production transportation and public use are controlled to avoid that introducing hydrogen as energy carrier should pose unacceptable risk to the society.<br/>History has proven that introducing risk analysis to new industries is beneficial e.g. in transportation and power production and distribution. However this will require existing methods and standards to be adapted to the specific applications. Furthermore when trying to quantify risk it is of utmost importance to have access to relevant accident and incident information. Such data may in many cases not be readily available and the utilisation of them will then require specific and long lasting data collection initiatives.<br/>In this paper we will present the work that has been undertaken in the HySafe project in developing methodologies and collecting data for risk management of hydrogen infrastructure. Focus is laid on the development of risk acceptance criteria and on the demonstration of safety and benefits to the public. A trustworthy demonstration of safety will have to be based on facts especially on facts widely known and emphasis will thus be put on the efforts taken to establish and operate a database containing hydrogen accident and incident information which can be utilised in risk assessment of hydrogen applications. A demonstration of safety will also have to include a demonstration of risk control measures and the paper will also present work carried out on safety distances and ignition source control.
Impact of Hydrogen Injection on Natural Gas Measurement
Dec 2021
Publication
Hydrogen is increasingly receiving a primary role as an energy vector in ensuring the achievement of the European decarbonization goals by 2050. In fact Hydrogen could be produced also by electrolysis of water using renewable sources such as photovoltaic and wind power being able to perform the energy storage function as well as through injection into natural gas infrastructures. However hydrogen injection directly impacts thermodynamic properties of the gas itself such as density calorific value Wobbe index sound speed etc. Consequently this practice leads to changes in metrological behavior especially in terms of volume and gas quality measurements. In this paper the authors present an overview on the impact of hydrogen injection in natural gas measurements. In particular the changes in thermodynamic properties of the gas mixtures with different H2 contents have been evaluated and the effects on the accuracy of volume conversion at standard conditions have been investigated both on the theoretical point of view and experimentally. To this end the authors present and discuss the effect of H2 injection in gas networks on static ultrasonic domestic gas meters both from a theoretical and an experimental point of view. Experimental tests demonstrated that ultrasonic gas meters are not significantly affected by H2 injection up to about 10%.
Hydrogen Transport Safety: Case of Compressed Gaseous Tube Trailer
Sep 2005
Publication
The following paper describes researches to evaluate the behaviour under various accidental conditions of systems of transport compressed hydrogen. Particularly have been considered gaseous tube trailer and the packages cylinders employed for the road transport which have an internal gas pressures up to 200 barg.<br/>Further to a verification of the actual safety conditions this analysis intends to propose a theme that in the next future if confirmed projects around the employment of hydrogen as possible source energetic alternative could become quite important. The general increase of the consumptions of hydrogen and the consequently probable increase of the transports of gaseous hydrogen in pressure they will make the problem of the safety of the gaseous tube trail particularly important. Gaseous tube trailers will also use as components of plant. for versatility easy availability' and inexpensiveness.<br/>The first part of the memory is related to the analysis of the accidents happened in the last year in Italy with compressed hydrogen transports and particularly an accurate study has been made on the behaviour of a gaseous tube trailer involved in fire following a motorway accident in March 2003. In the central part of the job has been done a safety analysis of the described events trying to make to also emerge the most critical elements towards the activities developed by the teams of help intervened.<br/>Finally in the last part you are been listed on the base of the picked data a series of proposals and indications of the possible structural and procedural changes that could be suggested with the purpose to guarantee more elevated safety levels.
A Reappraisal of Containment Safety Under Hydrogen Detonation
Sep 2005
Publication
The response of a typical steel-lined reinforced concrete nuclear reactor containment to postulated internal hydrogen detonations is investigated by detailed axisymetric non-linear dynamic finite element analysis. The wall pressure histories are calculated for hydrogen detonations using a technique that reproduces the sharp discontinuity at the shock front. The pressure results can be applied to geometrically similar vessels. The analysis indicates that the response is more sensitive to the point of initiation than to the strength of the detonation. Approximate solutions based on a pure impulse assumption where the containment is modelled as a single-degree-of freedom (SDOF) system may be seriously unconservative. This work becomes relevant because new nuclear reactors are foreseen as a primary of source of hydrogen supply.<br/><br/>
Guidelines for Fire Corps Standard Operating Procedures in the Event of Hydrogen Releases
Sep 2007
Publication
This paper presents a study on the Standard Operating Procedures (P.O.S.s) for the operation of the Fire Corps squads in the event of accidents with a hydrogen release fire or explosion. This study has been carried out by the Italian Working Group on the fire prevention safety issues as one of its main objectives. The Standard Operating Procedures proved to be a basic tool in order to improve the effectiveness of the Fire Corps rescue activity. The unique physical and chemical properties of the hydrogen its use without odorization and its almost invisible flame require a review of the already codified approaches to the rescue operations where conventional gases are involved. However this is only the first step; a Standard Operating Procedure puts together both the theoretical and practical experience achieved on the management of the rescue operations; therefore its arrangement is a cyclic process by nature always under continuous revision updating and improvement.
Simulator Development of Virtual Experience and Accident Scenarios of Hydrogen Stations for Safety
Sep 2007
Publication
Nowadays 4 type hydrogen stations have been demonstrated in Korea for preparing hydrogen economy. This simulator is consists of virtual experience modules and virtual accident scenarios of 4 type hydrogen stations. Virtual experience modules show the performance properties through a movie or a virtual reality technology. Also they provide an explanation of hydrogen station equipment and a guide for operators immediately after the accident. Virtual accident scenario modules show accident simulations based on modelling equations as 3D virtual reality. These modules could choose the sham accident for every kind of a station after categorizing all possible accidents in a station A Commercialized CFD program based on hydrogen dispersion model theory shows a movie of accident simulations. The result of a simulator has been developed as web applications. And will be applied to training materials and public relations for a user concerned about hydrogen stations.
Gas Build-up in a Domestic Property Following Releases of Methane/Hydrogen Mixtures
Sep 2007
Publication
The EC funded Naturalhy project is investigating the possibility of promoting the swift introduction of hydrogen as a fuel by mixing hydrogen with natural gas and transporting this mixture by means of the existing natural gas pipeline system to end-users. Hydrogen may then be extracted for use in hydrogen fuel cell applications or the mixture may be used directly in conventional gas-fired equipment. This means that domestic customers would receive a natural gas (methane)/hydrogen mixture delivered to the home. As the characteristics of hydrogen are different from natural gas there may be an increased risk to end-users in the event of an accidental release of gas from internal pipe work or appliances. Consequently part of the Naturalhy project is aimed at assessing the potential implications on the safety of the public which includes end-users in their homes. In order to understand the nature of any gas accumulation which may form and identify the controlling parameters a series of large scale experiments have been performed to study gas accumulations within a 3 m by 3 m by 2.3 m ventilated enclosure representing a domestic room. Gas was released vertically upwards at a pressure typical of that experienced in a domestic environment from hole sizes representative of leaks and breaks in pipe work. The released gas composition was varied and included methane and a range of methane/hydrogen mixtures containing up to 50% hydrogen. During the experiments gas concentrations throughout the enclosure and the external wind conditions were monitored with time. The experimental data is presented. Analysis of the data and predictions using a model developed to interpret the experimental data show that both buoyancy and wind driven ventilation are important.
Influence of Temperature on the Fatigue Strength of Compressed Hydrogen Tanks for Vehicles
Sep 2009
Publication
The influence of environmental temperatures on the fatigue strength of compressed-hydrogen tanks for vehicles was investigated. The fatigue strength of Type-3 tanks was found to decrease in a low temperature environment and increase in a high-temperature environment. The Type-3 tank has been subjected to autofrettage to improve fatigue strength. The investigation clarified that the effect of autofrettage changes according to the environmental temperature due to the difference between the coefficients of thermal expansion of carbon fiber reinforced plastic (CFRP) and aluminum alloy. This causes life strength to change with changes in temperature. These results indicate that the service life of the Type-3 tank is influenced by the environmental temperature. The Type-4 tank has a very long fatigue life and did not break after 45000 cycles in a room-temperature or low-temperature environment. In a high-temperature environment however the tank broke in fewer than 45000 cycles. The fatigue of CFRP was promoted in the high-temperature environment resulting in breakage of the tank.
Addressing Hydrogen Embrittlement of Metals in the Sae J2579 Fuel Cell Vehicle Tank Standard
Sep 2013
Publication
The SAE Technical Information Report (TIR) J2579 (Technical Information Report for Fuel Systems in Fuel Cell and Other Hydrogen Vehicles) has been created to address the safety performance of hydrogen storage and handling systems on vehicles. Safety qualification of the compressed hydrogen storage system is demonstrated through performance testing on prototype containment vessels. The two performance tests currently included in the SAE J2579 for evaluating unacceptable leakage and burst do not account for the potential effects of hydrogen embrittlement on structural integrity. This report describes efforts to address hydrogen embrittlement of structural metals in the framework of performance-based safety qualification. New safety qualification pathways that account for hydrogen embrittlement in the SAE J2579 include an additional pneumatic performance test using hydrogen gas or materials tests that demonstrate acceptable hydrogen embrittlement resistance of candidate structural metals.
Study of Hydrogen Diffusion and Deflagration in a Closed System
Sep 2007
Publication
A total of 12 ventilation experiments with various combinations of hydrogen release rates and ventilation speeds were performed in order to study how ventilation speed and release rate effect the hydrogen concentration in a closed system. The experiential facility was constructed out of steel plates and beams in the shape of a rectangular enclosure. The volume of the test facility was about 60m3. The front face of the enclosure was covered by a plastic film in order to allow visible and infrared cameras to capture images of the flame. The inlet and outlet vents were located on the lower front face and the upper backside panel respectively. Hydrogen gas was released toward the ceiling from the center of the floor. The hydrogen gas was released at constant rate in each test. The hydrogen release rate ranged from 0.002 m3/s to 0.02 m3/s. Ventilation speeds were 0.1 0.2 and 0.4 m3/s respectively. Ignition was attempted at the end of the hydrogen release by using multiple continuous spark ignition modules on the ceiling and next to the release point. Time evolution of hydrogen concentration was measured using evacuated sample bottles. Overpressure and impulse inside and outside the facility were also measured. The mixture was ignited by a spark ignition module mounted on the ceiling in eight of eleven tests. In the other three tests the mixture was ignited by spark ignition modules mounted next to the nozzle. Overpressures generated by the hydrogen deflagration in most of these tests were low and represented a small risk to people or property. The primary risk associated with the hydrogen deflagrations studied in these tests was from the fire. The maximum concentration is proportional to the ratio of the hydrogen release rate to the ventilation speed within the range of parameters tested. Therefore a required ventilation speed can be estimated from the assumed hydrogen leak rate within the experimental conditions described in this paper.
Hydrogen Related Risks Within a Private Garage: Concentration Measurements in a Realistic Full Scale Experimental Facility
Sep 2007
Publication
Next generation of hydrogen energy based vehicles is expected to come into widespread use in the near future. Various topics related to hydrogen including production storage and application of hydrogen as an energy carrier have become subjects of discussion in the framework of various European and International projects. Safety information is vital to support the successful introduction into mainstream and public acceptance of hydrogen as an energy carrier. One of such issues which is seeking major attention is related to hydrogen powered vehicles parked inside a confined area (such as in a private garage). It is of utmost importance to predict if uncontrolled release of hydrogen from a vehicle parked inside a confined area can create an explosive atmosphere. Subsequently how the preventive measures can be implied to control these explosive atmospheres if present inside a confined area? There is a little guidance currently developed for confined areas accommodating hydrogen fuelled vehicles. It is essential that mitigation measures for such conditions become established.<br/>Characterization of different scenarios those may arise in a real situation from hydrogen fuelled vehicle parked inside a garage and furthermore the investigation of an optimal ventilation rate for hydrogen risk mitigation are some of the main objectives described in the framework of the present study. This work is an effort to provide detail experimental information’s in view of establishing guidelines for hydrogen powered vehicles parked inside a private garage. The present work is developed in the framework of a European Network of Excellence HySafe and French project DRIVE. Present paper describes a purpose built realistic Garage test facility at CEA to study the dispersion of hydrogen leakage. The studied test cases evaluate the influence of injected volumes of hydrogen and the initial conditions at the leakage source on the dispersion and mixing characteristics inside the free volume of the unventilated garage. The mixing process and build-up of hydrogen concentration is measured for the duration of 24 hours. Due to safety reasons helium gas is used to simulate the hydrogen dispersion characteristics.
A Numerical Simulation on the Leakage Event of a High-Pressure Hydrogen Dispenser
Dec 2021
Publication
For the sake of the increasing demand of hydrogen fuel cell vehicles there are more concerns on the safety of hydrogen refueling stations. As one of the key pieces of equipment the hydrogen dispenser has drawn attention on this aspect since it involves massive manual operations and may be bothered by a high probability of failure. In this paper a numerical study is conducted to simulate the possible leakage events of the hydrogen dispenser based on a prototype in China whose working pressure is 70 MPa. The leakage accident is analyzed with respect to leakage sizes leak directions and the time to stop the leakage. It is found that due to the large mass flow rate under such high pressure the leak direction and the layout of the components inside the dispenser become insignificant and the ignitable clouds will form inside the dispenser in less than 1 s if there is a leakage of 1% size of the main tube. The ignitable clouds will form near the vent holes outside the dispenser which may dissipate quickly if the leakage is stopped. On the other hand the gas inside the dispenser will remain ignitable for a long time which asks for a design with no possible ignition source inside. The results can be useful in optimizing the design of the dispenser regarding the reaction time and sensitivity requirements of the leakage detector the size and amount of vent holes etc.
Quantification of the Uncertainty of the Peak Pressure Value in the Vented Deflagrations of Air-Hydrogen Mixtures
Sep 2007
Publication
In the problem of the protection by the consequences of an explosion is actual for many industrial application involving storage of gas like methane or hydrogen refuelling stations and so on. A simple and economic way to reduce the peak pressure associated to a deflagration is to supply to the confined environment an opportune surface substantially less resistant then the protected structure typically in stoichiometric conditions the peak pressure reduction is around the 8 bars for a generic hydrocarbon combustion in an adiabatic system lacking of whichever mitigation system. In general the problem is the forecast of the peak pressure value (PMAX) of the explosion. This problem is faced using CFD codes modelling the structure in which the explosion is located and setting the main parameters like concentration of the gas in the mixture the volume available the size of vent area and obstacles (if included) and so on. In this work the idea is to start from empirical data to train a Neural Network (NN) in order to find the correlation among the parameters regulating the phenomenon. Associated to this prediction a fuzzy model will provide to quantify the uncertainty of the predicted value.
Facilitating the Safest Possible Transition from Fossil to Hydrogen Fuels- Hydrogen Executive Leadership Panel
Sep 2005
Publication
In recent years federal and state safety authorities have worked to bring emergency planners and responders together with industry the scientific community and consumers to ensure high levels of safety with gas and liquid pipelines and more recently with liquefied natural gas terminals. The U.S. Department of Transportation (DOT) is the federal authority on the safe transportation of energy and the National Association of State Fire Marshals (NASFM) represents state-level safety authorities. Together they have produced firefighter safety training materials technical guidance and information for use in communities considering new energy infrastructure and conducted research to support these activities. In 2004 the DOT-NASFM partnership established the Hydrogen Executive Leadership Panel (HELP) to ensure a safe transition from fossil fuels to hydrogen fuel cells. HELP brings together senior policy-level experts from all sectors to understand and recommend mitigation strategies for the risks associated with the transportation and use of hydrogen in motor vehicles. The initial group includes experts from the United States Canada and Europe. HELP will be supported by an advisory committee of emergency planners and responders—individuals well-equipped to describe real-world scenarios of greatest concern—and by a second advisory committee of engineers and scientists who will help translate the real-world scenarios into useful technical solutions. By September 2005 HELP expects to define the initial real-world scenarios of greatest concern and bring together teams of experts to collaborate with automakers energy producers government authorities consumers and public safety officials. Much work lies ahead including creating guidance for hydrogen powered automobiles emergency response safety training establishing test methods to reflect real-world incident scenarios and modifying state and local building and fire codes. The HELP leadership will present its strategic plan and first report at the International Conference on Hydrogen Safety in September 2005.
Green Hydrogen Value Chain in the Sustainability for Port Operations: Case Study in the Region of Valparaiso, Chile
Dec 2021
Publication
The paper presents a complete value chain for the use of green hydrogen in a port facility. The main objective was to propose the sizing of the main components that make up green hydrogen to ensure the supply of 1 MWe in replacing the diesel generator. The energy demand required for the port was determined by establishing the leading small and large-scale conventional energyconsuming equipment. Hence 60 kgH2 was required to ensure the power supply. The total electrical energy to produce all the hydrogen was generated from photovoltaic solar energy considering threegeneration scenarios (minimum maximum and the annual average). In all cases the energy supply in the electrolyzer was 3.08 MWe. In addition the effect of generating in the port facility using a diesel generator and a fuel cell was compared. The cost of 1 kgH2 could be 4.09 times higher than the cost of 1 L of diesel meaning that the output kWh of each system is economically similar. In addition the value of electrical energy through a Power Purchase Agreement (PPA) was a maximum of 79.79 times the value of a liter of diesel. Finally the Levelized Cost of Energy (LCOE) was calculated for two conditions in which the MWe was obtained from the fuel cell without and with the photovoltaic solar plant.
Safety of Laboratories for New Hydrogen Techniques
Sep 2007
Publication
In this paper a case of hydrogen release in a typical research laboratory for the characterisation of hydrogen solid-state storage materials has been considered. The laboratory is equipped with various testing equipments for the assessment of hydrogen capacity in materials typically in the 1 to 200 bar pressure range and temperatures up to 500°C. Hydrogen is delivered at 200 bar by a 50 l gas bottle and a compressor located outside the laboratory. The safety measures directly related to hydrogen hazard consist in a distributed ventilation of the laboratory and air extraction fume hoods located on top of each instrument. Goal of this work is the modelling of hydrogen accidental release in a real laboratory case in order to provide a more fundamental basis for the laboratory safety design and assist the decision on the number and position of the safety sensors. The computational fluid dynamics code (CFD) ANSYS-CFX has been selected in order to perform the numerical investigations. Two basic accidental release scenarios have been assumed both at 200 bar: a major leak corresponding to a guillotine breaking of the hydrogen distribution line and a smaller leak typical for a not properly tight junction.
Overview of the New Combined Gasoline/Hydrogen Supply Station and Relevant Regulations in Japan
Sep 2007
Publication
When a hydrogen supply station is to be installed in Japan three fundamental laws must be taken into consideration: the High Pressure Gas Safety Law the Building Standards Law and the Fire Service Law. The High Pressure Gas Safety Law in particular regulates procedures for safety concerning hydrogen supply stations. This law came under review accompanying consideration of the potential utilization of fuel cell vehicles and hydrogen stations. At that time the Japan Petroleum Energy Center (JPEC) investigated safety technology for hydrogen supply stations and prepared a draft of the law. Since then a new combined gasoline/hydrogen supply station compliant with the revised law was established on December 2006. There are a large number of safety precautions incorporated into this station model which conform to the law. As a result of these modifications it was possible to reduce the safe setback distance. In this paper we present an overview of the new hydrogen supply station model the safety precautions and the regulations the station is based on.
No more items...