Skip to content
1900

Effects of the Injector Direction on the Temperature Distribution During Filling of Hydrogen Tanks

Abstract

The development of the temperature field in hydrogen tanks during the filling process has been investigated with Computational Fluid Dynamics (CFD). Measurements from experiments undertaken at the JRC GasTef facility have been used to develop and validate the CFD modelling strategy; by means of the CFD calculations, the effect of the injector direction on the temperature distribution has been analysed. It has been found that the dynamics of the temperature field, including the development of potentially detrimental phenomena like thermal stratification and temperature inhomogeneity e.g. hot spots, can be significantly affected by the injector orientation.

Related subjects: Safety
Countries: Netherlands
Loading

Article metrics loading...

/content/conference825
2017-09-12
2024-11-25
/content/conference825
Loading

Supplements

Effects of the injector direction on the temperature distribution during filling of hydrogen tanks

This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error