Skip to content
1900

Temperature Change of a Type IV Cylinder During Hydrogen Fuelling Process

Abstract

The temperature of the hydrogen cylinder needs to be carefully controlled during fuelling process. The maximum temperature should be less than 85℃ according to the ISO draft code. If the fuelling period is reduced, the maximum temperature should increase. In this study, temperature change of a Type IV cylinder was measured during the hydrogen fuelling process up to 35 MPa. Fuelling period was 3 to 5 minutes. Twelve thermocouples were installed to measure inside gas temperature and seven were attached on the outside of the cylinder. An infrared camera was also used for measuring temperature distribution of outside of cylinder. The maximum gas temperature was higher than 85℃ inside of the cylinder. Significant temperature difference between the upper and lower part of the vessel was observed. Temperature near the plug and the valve was quickly increased and maintained higher than that of the other region. Temperature increases for the partial refuelling process were also discussed.

Related subjects: Safety
Countries: Korea, Republic of
Loading

Article metrics loading...

/content/conference449
2009-09-17
2024-12-27
/content/conference449
Loading
This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error