Skip to content
1900

Vented Hydrogen-air Deflagration in a Small Enclosed Volume

Abstract

Since the rapid development of hydrogen stationary and vehicle fuel cells the last decade, it is of importance to improve the prediction of overpressure generated during an accidental explosion which could occur in a confined part of the system. To this end, small-scale vented hydrogen–air explosions were performed in a transparent cubic enclosure with a volume of 3375 cm3. The flame propagation was followed with a high speed camera and the overpressure inside the enclosure was recorded using high frequency piezoelectric transmitters. The effects of vent area and ignition location on the amplitude of pressure peaks in the enclosed volume were investigated. Indeed, vented deflagration generates several pressures peaks according to the configuration and each peak can be the dominating pressure. The parametric study concerned three ignition locations and five square vent sizes.

Related subjects: Safety
Countries: France
Loading

Article metrics loading...

/content/conference575
2013-09-13
2024-11-21
/content/conference575
Loading

Supplements

Vented hydrogen-air deflagration in  a small enclosed volume

This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error